Product Description:
The 2-Way Valve allows water to flow to the boiler this part is also known as "autofill valve."
Fits:
Pasquini Livia 90, Livia G4, Strega, Mitica, and Magica machines.
Symptoms of this part failing:
- The boiler is not able to fill when pump comes on, which means pump will continue to run because valve is not opening.
- b - Boiler may overfill when valve is stuck open causing water to flow in boiler when brewing.
- c - Pump will continue running not able to fill Boiler, and your group is able to work at the same time. which means your pump is working.











Reviews